AlertFox is part of the Ipswitch family of tools and services. Learn More »

Web Interface and Backend FAQ

What browsers do you run on the backend?

A: Please see the backend monitoring server page for details.

How can I disable/enable monitoring for many sensors at once?

The fastest method for doing this is to navigate to your sensor page and then run this iMacros macro via the “LOOP” button. You can adjust the start and end values to match the range of sensors you want to disable/enable.

VERSION BUILD=6301104 RECORDER=FX
URL GOTO=http://www.alertfox.com/EditAccountSensors
TAG POS={{!LOOP}} TYPE=A ATTR=TXT:Edit
'This lines DISables monitoring
TAG POS=1 TYPE=INPUT:CHECKBOX FORM=NAME:form1 ATTR=ID:ctl03_ctl00_dvDetail_cbMonitoringEnabled CONTENT=NO
'This line enables monitoring again
'TAG POS=1 TYPE=INPUT:CHECKBOX FORM=NAME:form1 ATTR=ID:ctl03_ctl00_dvDetail_cbMonitoringEnabled CONTENT=YES
TAG POS=1 TYPE=INPUT:SUBMIT FORM=ID:form1 ATTR=ID:ctl03_ctl00_dvDetail_btUpdate
Of course, the same approach can be used for any other mass changes in your AlertFox account.

How do I change my account password?

Go to the Logins > Add or Edit Control Panel Logins page. Click edit next to your user ID. A popup will open where you can change your password.